{"id":6910,"date":"2021-07-07T12:30:50","date_gmt":"2021-07-07T15:30:50","guid":{"rendered":"http:\/\/escolasesc.com.br\/?p=5753"},"modified":"2021-07-07T12:30:50","modified_gmt":"2021-07-07T15:30:50","slug":"concorrencia-no-21e-0006cc","status":"publish","type":"post","link":"https:\/\/www.sesc.com.br\/poloeducacional\/concorrencia-no-21e-0006cc\/","title":{"rendered":"Concorr\u00eancia N\u00ba 21E\/0006CC"},"content":{"rendered":"<p style=\"text-align: center;\"><strong>\u00a0RESULTADO DA FASE\u00a0HABILITA\u00c7\u00c3O E JULGAMENTO FINAL<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc informa o resultado da habilita\u00e7\u00e3o da licita\u00e7\u00e3o em ep\u00edgrafe:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><strong><u>Empresa Habilitada:<\/u><\/strong><\/p>\n<p style=\"text-align: center;\"><em>TORRES ENGENHARIA E CONSULTORIA LTDA<\/em><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">Diante do exposto, O Polo Educacional Sesc informa o resultado Final da licita\u00e7\u00e3o acima referenciada:<\/p>\n<p style=\"text-align: center;\"><strong><u>Julgamento Final:\u00a0<\/u><\/strong><em>\u00a0<\/em><\/p>\n<p style=\"text-align: center;\"><em>TORRES ENGENHARIA E CONSULTORIA LTDA<\/em><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">Rio de Janeiro, 13 de setembro de 2021.<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><strong>RESULTADO DA FASE DE CLASSIFICA\u00c7\u00c3O DE PROPOSTAS<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc, informa o resultado da an\u00e1lise das propostas comerciais da licita\u00e7\u00e3o em ep\u00edgrafe, cujos envelopes \u201cProposta Comercial\u201d foram abertos em reuni\u00e3o realizada no dia 19\/08\/2021 \u00e0s 10 horas:<\/p>\n<p style=\"text-align: center;\"><strong><u>Empresas Classificadas:<\/u><\/strong><\/p>\n<p style=\"text-align: center;\"><em>TORRES ENGENHARIA E CONSULTORIA LTDA<\/em><\/p>\n<p style=\"text-align: center;\"><em>CRATER CONSTRU\u00c7\u00d5ES LTDA<\/em><\/p>\n<p style=\"text-align: center;\"><i>ESPECTRO ENGENHARIA LTDA<\/i><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><strong><u>Empresas Desclassificadas:<\/u><\/strong><\/p>\n<p style=\"text-align: center;\"><em>LUMINUS ELETRICIDADE, GERADORES E SERVI\u00c7OS EIRELI<\/em><\/p>\n<p style=\"text-align: center;\"><em>CONSTRUTORA BRASFORM LTDA<\/em><\/p>\n<p style=\"text-align: center;\"><em>ZANELI SERVI\u00c7OS EL\u00c9TRICOS LTDA<\/em><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">Consequentemente, o Polo Educacional Sesc, informa a data e hor\u00e1rio para abertura do envelope \u201cDocumentos de Habilita\u00e7\u00e3o\u201d, conforme previsto no subitem 5.4.2 do Edital, no\u00a0<strong>dia 02 de setembro de 2021, \u00e0s 10:00 horas.<\/strong><\/p>\n<p style=\"text-align: center;\">Rio de Janeiro, 25 de agosto de 2021.<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>ADENDO IX<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc responde ao questionamento apresentado por empresa interessada em participar desta licita\u00e7\u00e3o.<\/p>\n<p class=\"x_xmsonormal\">Pergunta: Como forma de comprova\u00e7\u00e3o do v\u00ednculo profissional\/empresa, para efeito de atendimento do item \u201cb\u201d do item 3.2 \u201cQualifica\u00e7\u00e3o t\u00e9cnica\u201d do edital, ser\u00e1 aceita declara\u00e7\u00e3o de compromisso futuro de profissional detentor de atestado t\u00e9cnico compat\u00edvel com o objeto do edital com a Licitante caso sejamos consagrados vencedores do certame, como j\u00e1 previsto em editais de processos licitat\u00f3rios anteriores deste mesmo Sesc. Est\u00e1 correto nosso entendimento?<\/p>\n<p class=\"x_xmsonormal\"><strong>Resposta.:<\/strong> <strong>N\u00e3o. O(s) profissional(is) que for(em) relacionado(s) para efeito de comprova\u00e7\u00e3o de capacidade t\u00e9cnica dever\u00e1(\u00e3o) possuir v\u00ednculo com a empresa proponente.<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">Rio de Janeiro, 12 de agosto de 2021.<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>ADENDO VIII<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc informa:<\/p>\n<ul>\n<li>Publica\u00e7\u00e3o de anexos Ib, Ic e Id revisados, atrav\u00e9s do link\u00a0<a href=\"https:\/\/drive.google.com\/drive\/folders\/1GMlbhze-0kiYJawx9dY8ZzmYEkZrS5Hp\" target=\"_blank\" rel=\"noopener\">https:\/\/drive.google.com\/drive\/folders\/1GMlbhze-0kiYJawx9dY8ZzmYEkZrS5Hp<\/a><\/li>\n<\/ul>\n<p style=\"text-align: center;\">Rio de Janeiro, 12 de agosto de 2021.<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>ADENDO VII<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc responde aos questionamentos apresentado por empresas interessadas em participar desta licita\u00e7\u00e3o.<\/p>\n<p style=\"text-align: left;\">Pergunta: Ao analisarmos a Planilha de Servi\u00e7os (<strong><u>referencial<\/u><\/strong>), verificamos que os itens tais como: Cabos de M\u00e9dia Tens\u00e3o; Transformadores \u00e0 Seco; Pain\u00e9is de Baixa Tens\u00e3o (itens: 2.1.1 , 2.1.1.2, 2.1.1.3, 2.1.1.4 \/ 2.3.4.3.1, 2.3.10.1 \/ 2.4.4.3, 2.4.4.3.1, 2.4.10.1 \/ 2.6.5.1.1), est\u00e3o com pre\u00e7os abaixo do praticado atualmente no mercado. Isto posto, solicitamos a revis\u00e3o\/ atualiza\u00e7\u00e3o de pre\u00e7os destes itens conforme pre\u00e7os atuais de mercado.<\/p>\n<p style=\"text-align: left;\"><strong>Resposta.: Estamos republicando nesta data a planilha do or\u00e7amento de refer\u00eancia ajustada para compensar as defasagens apontadas.<\/strong><\/p>\n<p style=\"text-align: left;\">Pergunta: Ao fazermos a verifica\u00e7\u00e3o dos quantitativos, na planilha de quantidade do referido memorial descritivo, verificamos diverg\u00eancia entre o item 2.2.4.2.3 da planilha e o item 5.1.7-b do Memorial Descritivo. O Item 2.2.4.2.3 da planilha\u00a0de pre\u00e7o \u2013\u00a0\u201c<em>Cabos el\u00e9tricos 0,6\/1kV constitu\u00eddo por condutor de cobre nu, t\u00eampera mole, classe 5 extra flex\u00edvel, isola\u00e7\u00e3o em composto termofixo HEPR 90\u00b0C e cobertura em composto termopl\u00e1stico \u00a0n\u00e3o \u00a0halogenado, \u00a0conforme \u00a0normas \u00a0NBR \u00a013248, \u00a0NBR \u00a013570 \u00a0e NBR 5410 de 150 mm2\u201d \u2013<\/em>\u00a0apresenta uma quantidade prevista de 2.500,00 metros enquanto o item 5.1.7-b do Memorial Descritivo, a metragem do cabo com di\u00e2metro\u00a0de 150mm2\u00a0foi previsto, para esta subesta\u00e7\u00e3o, uma quantidade de 5.040,00 metros.<\/p>\n<p style=\"text-align: left;\"><strong>Resposta.: Dever\u00e1 ser considerado na proposta as quantidades do or\u00e7amento de refer\u00eancia.<\/strong><\/p>\n<p style=\"text-align: left;\">Pergunta: Qual a quantidade efetiva a ser considerada, visto que na descri\u00e7\u00e3o do referido item,\u00a0preconiza que temos que estar em conformidade com o Memorial Descritivo?<\/p>\n<p style=\"text-align: left;\"><strong>Resposta.: Dever\u00e1 ser considerado na proposta as quantidades do or\u00e7amento de refer\u00eancia.<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">Rio de Janeiro, 12 de agosto de 2021.<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>A D I A M E N T O\u00a0<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc informa o adiamento da Reuni\u00e3o de Recebimento de Envelopes para:<\/p>\n<p style=\"text-align: center;\"><strong>19 de agosto de 2021, \u00e0s 10 horas<\/strong><\/p>\n<p style=\"text-align: center;\">Rio de Janeiro, 05 de agosto de 2021.<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>ADENDO VI<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc prorroga a data deste processo licitat\u00f3rio, conforme abaixo:<\/p>\n<ul style=\"text-align: center;\">\n<li style=\"text-align: left;\">Prorroga\u00e7\u00e3o do prazo de visita t\u00e9cnica, item 3.2.2 do Edital &#8211; <strong>at\u00e9 02\/08\/2021<\/strong>;<\/li>\n<li style=\"text-align: left;\">Adiamento da Reuni\u00e3o de Recebimento de Envelopes para o\u00a0<strong>dia 09 de agosto de 2021, \u00e0s 10:00 horas<\/strong>, item 5.1 do Edital;<\/li>\n<li style=\"text-align: left;\">Link de acesso aos documentos do Anexo Ia revisado com os projetos em DWG, item 8.16 do Edital;<\/li>\n<\/ul>\n<p style=\"text-align: center;\">Rio de janeiro, 27 de julho de 2021<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>ADENDO V<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc responde aos questionamentos apresentado por empresas interessadas em participar desta licita\u00e7\u00e3o.<\/p>\n<p>Pergunta: De acordo com os documentos disponibilizados (Memorial descritivo, projetos), os Quadros Gerais de Baixa Tens\u00e3o, Cub\u00edculos de M\u00e9dia Tens\u00e3o e Transformadores que poder\u00e3o ser substitu\u00eddos ser\u00e3o alocados para um dep\u00f3sito ou ser\u00e1 responsabilidade da Contratada efetuar o descarte devido dos itens?<\/p>\n<p><strong>Resposta: Os equipamentos que ser\u00e3o substitu\u00eddos dever\u00e3o ser avaliados previamente pela Contratante, caso n\u00e3o sejam do interesse da manuten\u00e7\u00e3o da Escola, dever\u00e3o ser descartados sob total responsabilidade da Contratada.<\/strong><\/p>\n<p>Pergunta: Na forma\u00e7\u00e3o de pre\u00e7os de homem-hora para equipe local, notamos que o c\u00e1lculo foi feito com encargos complementares. Solicitamos conhecer o percentual utilizado para o c\u00e1lculo destes encargos e se, nesta composi\u00e7\u00e3o, o valor de periculosidade foi considerado.<\/p>\n<p><strong>Resposta: S\u00e3o utilizadas as composi\u00e7\u00f5es, insumos e encargos sociais do SINAPI, publicados no site da caixa e de livre acesso a consultas de qualquer pessoa.<\/strong><\/p>\n<p>Pergunta: Dada a escassez de metal no mercado e varia\u00e7\u00f5es de pre\u00e7o de equipamentos em fun\u00e7\u00e3o do d\u00f3lar e euro, solicitamos conhecer a f\u00f3rmula de reajuste de custo de produtos a ser utilizada para este projeto, caso aplic\u00e1vel.<\/p>\n<p><strong>Resposta: N\u00e3o aplic\u00e1vel<\/strong><\/p>\n<p>Pergunta: Dado o peso significativo dos equipamentos e cabos no valor deste projeto (superior a 60% do custo global) e visando\u00a0minimizar riscos de fluxo de caixa\u00a0associado \u00e0 compra de equipamentos e cabos, entendemos que\u00a0os boletins de medi\u00e7\u00e3o de avan\u00e7o de obra\u00a0devem\u00a0andar a par e passo com\u00a0a necessidade de fluxo de caixa da obra. Ou seja, o pagamento feito pelo SESC dever\u00e1 ser back-to-back com as condi\u00e7\u00f5es colocadas pelos fornecedores e isto pode significar, por exemplo, pagamento no fechamento do pedido e na entrega do equipamento, antes do comissionamento do equipamento. Favor confirmar entendimento.<\/p>\n<p><strong>Resposta: Poderemos atribuir um percentual referente ao peso de cada equipamento na composi\u00e7\u00e3o de pre\u00e7os, e efetuar o pagamento contra a entrega dos mesmos.<\/strong><\/p>\n<p>Pergunta: Entendemos que as obras devem ser feitas de forma seriada (n\u00e3o paralelizadas). Favor confirmar entendimento.<\/p>\n<p><strong>Resposta: Positivo, pois n\u00e3o podemos prejudicar a funcionalidade da Escola<\/strong><\/p>\n<p>Pergunta: Entendemos que as obras devem ser feitas no per\u00edodo diurno, de 2a a 6a, mesmo que a opera\u00e7\u00e3o do complexo SESC Barra esteja em opera\u00e7\u00e3o normal. Favor confirmar entendimento.<\/p>\n<p><strong>Resposta: Positivo, entretanto servi\u00e7os em finais de semana e jornada estendida poder\u00e3o ser executados, seguindo os procedimentos operacionais do Sesc e a legisla\u00e7\u00e3o trabalhista em vigor<\/strong><\/p>\n<p>Pergunta: Durante as obras, entendemos que uma determinada subesta\u00e7\u00e3o que esteja fora de aten\u00e7\u00e3o ser\u00e1 atendida por outra subesta\u00e7\u00e3o. O escopo de interliga\u00e7\u00e3o para by-pass desta subesta\u00e7\u00e3o e o atendimento das cargas originalmente por ela atendidas n\u00e3o \u00e9 escopo deste servi\u00e7o. Favor confirmar entendimento.<\/p>\n<p><strong>Resposta: A alimenta\u00e7\u00e3o poder\u00e1 ser feita atrav\u00e9s de outra subesta\u00e7\u00e3o que n\u00e3o esteja sob interven\u00e7\u00e3o, entretanto o by-pass e a alimenta\u00e7\u00e3o das cargas \u00e9 parte do escopo da contratada, sendo que para tal existe verba espec\u00edfica na planilha or\u00e7ament\u00e1ria. Para a subesta\u00e7\u00e3o SE-02 n\u00e3o h\u00e1, \u00e0 princ\u00edpio, disponibilidade suficiente em outras SEs, devendo a contratada prever uma forma de alimenta\u00e7\u00e3o provis\u00f3ria para tal. As cargas mais significativas na SE-06 s\u00e3o 3 (tr\u00eas) chillers de 300kW cada.<\/strong><\/p>\n<p>Pergunta: Entendemos que o SESC disponibilizar\u00e1 local, ainda que tempor\u00e1rio, para descarte dos materiais e dos equipamentos a serem retirados, sendo responsabilidade do contratado dar o devido tratamento quanto ao descarte final dos materiais. Favor confirmar entendimento.<\/p>\n<p><strong>Resposta: Positivo, entretanto a prioridade para este descarte tempor\u00e1rio ser\u00e1 a \u00e1rea destinada ao canteiro de obras<\/strong><\/p>\n<p>Pergunta: Na composi\u00e7\u00e3o 0077, entendemos que, ap\u00f3s a avalia\u00e7\u00e3o dos transformadores, caso o laudo final indique a necessidade de troca dos mesmos, ser\u00e1 de responsabilidade do SESC especific\u00e1-los, compr\u00e1-los e coloc\u00e1-los no local conforme projeto. Favor confirmar o entendimento.<\/p>\n<p><strong>Resposta: Negativo, a especifica\u00e7\u00e3o, aquisi\u00e7\u00e3o e transporte at\u00e9 o local ser\u00e1 de responsabilidade da contratada, que dever\u00e1 apresentar laudo t\u00e9cnico justificando a necessidade da troca. A aquisi\u00e7\u00e3o pela contratada, entretanto, somente dever\u00e1 ser feita ap\u00f3s a formaliza\u00e7\u00e3o de termo aditivo contratual.<\/strong><\/p>\n<p>Pergunta: N\u00e3o est\u00e3o dispon\u00edveis os desenhos em DWG para conferencias das medidas projetos\/ planilhas, uma vez que o link est\u00e1 em PDF. Como ficariam as eventuais diferen\u00e7as definidas nas planilhas em rela\u00e7\u00e3o as reais quantidades dos materiais\/componentes, como por exemplo, metragem de cabos, eletrocalhas.<\/p>\n<p><strong>Resposta: Estaremos disponibilizando os projetos em DWG para facilitar o levantamento e adiando a abertura dos envelopes para 09\/08\/2021, podendo as visitas ser realizadas at\u00e9 02\/08\/2021.<\/strong><\/p>\n<p>Pergunta: Valeriam ent\u00e3o os pre\u00e7os unit\u00e1rios das planilhas para os aditivos?<\/p>\n<p><strong>Resposta: Os pre\u00e7os unit\u00e1rios valer\u00e3o para aditivos em caso de altera\u00e7\u00f5es de escopo ap\u00f3s o contrato assinado, tendo como base de in\u00edcio a documenta\u00e7\u00e3o enviada no edital.<\/strong><\/p>\n<p>Pergunta: Solicitamos defini\u00e7\u00e3o\/informa\u00e7\u00e3o das correntes dos disjuntores reservas\/vagos nos diversos QGBT\u2019s, pois em fun\u00e7\u00e3o dos frames dos disjuntores reservas\/vagos haver\u00e1 altera\u00e7\u00e3o do dimensionamento, espa\u00e7amentos e bitola dos barramentos.<\/p>\n<p><strong>Resposta: Adotar um disjuntor com frame 25 a 100A como o padr\u00e3o para os disjuntores reservas.<\/strong><\/p>\n<p>Pergunta: Est\u00e3o representados em alguns dos circuitos de medi\u00e7\u00e3o nos novos QGBT\u2019s a serem fornecidos a utiliza\u00e7\u00e3o de TP\u2019s para 380V (?) e ainda sem prote\u00e7\u00e3o dos circuitos de tens\u00e3o dos multimedidores. Favor esclarecer.<\/p>\n<p><strong>Resposta: A utiliza\u00e7\u00e3o do TP tem como objetivo isolar o circuito de medi\u00e7\u00e3o do restante da instala\u00e7\u00e3o. \u00a0Com rela\u00e7\u00e3o a prote\u00e7\u00e3o, apesar de n\u00e3o indicada no desenho deve ser prevista atrav\u00e9s de disjuntores ou fus\u00edveis conforme orienta\u00e7\u00e3o do fabricante do multimedidor a ser fornecido.<\/strong><\/p>\n<p>Pergunta: Nos quadros de m\u00e9dia tens\u00e3o a serem fornecidos entendemos que deveram ser alteradas tanto a posi\u00e7\u00e3o el\u00e9trica dos TC\u2019s de prote\u00e7\u00e3o, bem como os indicadores buchas capacitivos dos indicadores de tens\u00e3o. Favor esclarecer.<\/p>\n<p><strong>Resposta: O fornecedor pode propor altera\u00e7\u00f5es desde estas atendam aos requisitos normativos vigentes.<\/strong><\/p>\n<p>Pergunta: Embora n\u00e3o conste do atual escopo dos servi\u00e7os o QGBT-SE-7.101 dever\u00e1 ser revisto, no que tange as correntes dos disjuntores em linha, bem como da chave transfer\u00eancia autom\u00e1tica motorizada, cuja a corrente nominal \u00e9 incompat\u00edvel com a pot\u00eancia do Nobreak.<\/p>\n<p><strong>Resposta: A\u00a0 CEE \u2013 Central de Energia Estabilizada ser\u00e1 objeto de contrata\u00e7\u00e3o futura, na\u00e3o fazendo parte do escopo desta Licita\u00e7\u00e3o.<\/strong><\/p>\n<p>Pergunta: Os intertravamentos dos disjuntores principais e respectivos Tie\u2019s, de caixa moldada, s\u00e3o garantidos para n\u00e3o paralelismo moment\u00e2neo apenas utilizando-se dispositivos KIRK para os 3 disjuntores com 2 chaves e mesmo segredo, enquanto que o el\u00e9trico poder\u00e1 eventualmente at\u00e9 permitir este paralelismo instant\u00e2neo. Seria aceito ent\u00e3o apenas o intertravemento KIRK?<\/p>\n<p><strong>Resposta: Dever\u00e1 ser utilizado intertravamento eletromec\u00e2nico.<\/strong><\/p>\n<p>Pergunta: Notamos algumas diverg\u00eancias entre o MEMORIAL DESCRITIVO, PLANILHA DE QUANTIDADES e UNIFILAR GERAL, para qual solicitamos ratifica\u00e7\u00e3o das potencias e servi\u00e7os espec\u00edficos nas respectivas subesta\u00e7\u00f5es, conforme descrito na planilha abaixo:<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"47\">\n<p style=\"text-align: center;\">SE<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"57\">EQUIP.<\/td>\n<td style=\"text-align: center;\" width=\"66\">QUANT.<\/td>\n<td style=\"text-align: center;\" width=\"189\">PLANILHADE QUANTIDADE<\/td>\n<td style=\"text-align: center;\" width=\"198\">MEMORIAL<\/td>\n<td style=\"text-align: center;\" width=\"132\">DESENHO<\/td>\n<\/tr>\n<tr>\n<td width=\"47\">\n<p style=\"text-align: center;\">SE\u20101<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"57\">TRAFO<\/td>\n<td style=\"text-align: center;\" width=\"66\">02<\/td>\n<td style=\"text-align: center;\" width=\"189\"><strong>2&#215;500 kVA<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"198\"><strong>2x300kVA<\/strong><\/td>\n<td width=\"132\">\n<p style=\"text-align: center;\"><strong>2x300kVA<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"47\">\n<p style=\"text-align: center;\">SE\u20102<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"57\">TRAFO<\/td>\n<td style=\"text-align: center;\" width=\"66\">02<\/td>\n<td style=\"text-align: center;\" width=\"189\">2X1000kVA<\/td>\n<td style=\"text-align: center;\" width=\"198\">Testar\/trocar se for o caso<\/td>\n<td width=\"132\">\n<p style=\"text-align: center;\">2x1000kVA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"47\">SE\u20102<\/td>\n<td style=\"text-align: center;\" width=\"57\">TRAFO<\/td>\n<td style=\"text-align: center;\" width=\"66\">02<\/td>\n<td style=\"text-align: center;\" width=\"189\"><strong>2x750kVA<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"198\"><strong>2x1000kVA<\/strong><\/td>\n<td width=\"132\">\n<p style=\"text-align: center;\"><strong>2x750kVA<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"47\">\n<p style=\"text-align: center;\">SE\u20104<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"57\">TRAFO<\/td>\n<td style=\"text-align: center;\" width=\"66\">02<\/td>\n<td style=\"text-align: center;\" width=\"189\">2&#215;112,5KVA<\/td>\n<td style=\"text-align: center;\" width=\"198\">Testar\/trocar se for o caso<\/td>\n<td style=\"text-align: center;\" width=\"132\">2&#215;112,5kVA<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"47\">SE\u20105<\/td>\n<td style=\"text-align: center;\" width=\"57\">TRAFO<\/td>\n<td style=\"text-align: center;\" width=\"66\">02<\/td>\n<td style=\"text-align: center;\" width=\"189\">2x500kVA<\/td>\n<td style=\"text-align: center;\" width=\"198\">Testar\/trocar se for o caso<\/td>\n<td width=\"132\">\n<p style=\"text-align: center;\">2x500kVA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"47\">SE\u20106<\/td>\n<td style=\"text-align: center;\" width=\"57\">TRAFO<\/td>\n<td style=\"text-align: center;\" width=\"66\">02<\/td>\n<td style=\"text-align: center;\" width=\"189\">2x225kVA<\/td>\n<td style=\"text-align: center;\" width=\"198\">Testar\/trocar se for o caso<\/td>\n<td width=\"132\">\n<p style=\"text-align: center;\">2x225kVA<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Resposta: Os transformadores da SE-1 dever\u00e3o ser substitu\u00eddos por 2 trafos de 300kVA.\u00a0<\/strong><\/p>\n<p><strong>Os transformadores existentes de 1.000kVA da SE-2 dever\u00e3o ser substitu\u00eddos para adequar as liga\u00e7\u00f5es do prim\u00e1rio e secund\u00e1rio, mas manter\u00e3o a sua pot\u00eancia, ou seja, 1.000kVA.<\/strong><\/p>\n<p><strong>Os transformadores existentes de 750kVA da SE-2 bem como os transformadores das demais subesta\u00e7\u00f5es dever\u00e3o ser testados e sua troca somente ocorrer\u00e1 se necess\u00e1rio, desde que devidamente justificado por Laudo t\u00e9cnico previamente aprovado pela Contratante.<\/strong><\/p>\n<p><span style=\"font-style: inherit; font-weight: inherit;\">Acerca do item 2.8.3 do anexo <strong>Ib:\u00a0Fornecimento de alimenta\u00e7\u00e3o provis\u00f3ria durante per\u00edodo de interven\u00e7\u00e3o nas Subesta\u00e7\u00f5es:<\/strong><\/span><\/p>\n<p><span style=\"font-style: inherit; font-weight: inherit;\">Pergunta:\u00a0Solicitamos descrever detalhadamente as necessidades para manter a alimenta\u00e7\u00e3o provis\u00f3ria das cargas alimentadas pelas Subesta\u00e7\u00f5es durante a execu\u00e7\u00e3o dos servi\u00e7os.\u00a0<\/span><span style=\"font-style: inherit; font-weight: inherit;\">Entendemos que, al\u00e9m do transformador de 750 kVA detalhado na planilha anal\u00edtica, iremos necessitar de cabos de BT e MT, pain\u00e9is provis\u00f3rios de BT e MT para atender ao solicitado no edital.<\/span><\/p>\n<p><span style=\"font-style: inherit; font-weight: inherit;\"><strong>Resposta: Cada subesta\u00e7\u00e3o \u00e9 respons\u00e1vel pela alimenta\u00e7\u00e3o el\u00e9trica de setores distintos no campus:<\/strong><\/span><\/p>\n<p><span style=\"font-style: inherit; font-weight: inherit;\"><strong>SE-01 alimenta os pr\u00e9dios da Coordena\u00e7\u00e3o, Casas de Professores e uma parte de ilumina\u00e7\u00e3o externa. Estas cargas poder\u00e3o eventualmente serem alimentadas provisoriamente atrav\u00e9s da SE-03 e para isto \u00e9 preciso prever cabos de baixa tens\u00e3o.<\/strong><\/span><\/p>\n<p><strong>SE-02 alimenta todas as utilidades do campus, sendo as mais relevantes: Central de \u00e1gua gelada (3 chillers 300kW), Central de V\u00e1cuo e Bombas de Inc\u00eandio. Devido \u00e0 pot\u00eancia dos equipamentos de \u00e1gua gelada, n\u00e3o h\u00e1 alternativa de alimenta\u00e7\u00e3o \u00e0 partir de outras SEs, sendo necess\u00e1rio prever uma fonte provis\u00f3ria (Trafo provis\u00f3rio ou gerador) e pain\u00e9is provis\u00f3rios de BT e MT.<\/strong><\/p>\n<p><strong>SE-04 alimenta o Gin\u00e1sio, ilumina\u00e7\u00e3o das quadras, canteiros de obras e uma parte de ilumina\u00e7\u00e3o externa. Estas cargas poder\u00e3o eventualmente serem alimentadas provisoriamente atrav\u00e9s da SE-03 ou SE-02 e para isto \u00e9 preciso prever cabos de baixa tens\u00e3o.<\/strong><\/p>\n<p><strong>SE-05 alimenta os pr\u00e9dios de Alojamento de alunos, Laborat\u00f3rios, Salas de Aula e Centro de Lideran\u00e7a e uma parte de ilumina\u00e7\u00e3o externa. Estas cargas poder\u00e3o serem alimentadas provisoriamente atrav\u00e9s da SE-06 e para isto \u00e9 preciso prever cabos de baixa tens\u00e3o.<\/strong><\/p>\n<p><strong>\u00a0<span style=\"font-style: inherit; font-weight: inherit;\">SE-06 alimenta o Teatro e uma parte de ilumina\u00e7\u00e3o externa. Estas cargas poder\u00e3o serem alimentadas provisoriamente atrav\u00e9s da SE-05 e para isto \u00e9 preciso prever cabos de baixa tens\u00e3o.<\/span><\/strong><\/p>\n<p><strong>SE-00 alimenta a Portaria e uma parte de ilumina\u00e7\u00e3o externa. Estas cargas ser\u00e3o alimentadas definitivamente atrav\u00e9s das SE-01 e SE-06 (uma reserva da outra). Sugerimos que esta seja executada ap\u00f3s a SE-01 ou SE-06.<\/strong><\/p>\n<p><strong>Por ser uma escola resid\u00eancia, todas as subesta\u00e7\u00f5es s\u00e3o cr\u00edticas e o tempo de parada para transfer\u00eancia de carga dever\u00e1 ser o menor poss\u00edvel preferencialmente, menor que 2 horas. Para o caso da SE-02, a criticidade \u00e9 ainda maior, sendo que para a Central de v\u00e1cuo o tempo de parada toler\u00e1vel \u00e9 menor do que 30 minutos.<\/strong><\/p>\n<p>\u00edtem 7.2 o anexo 1b &#8211; Planilha de Servi\u00e7os e Quantidades, explicita:<\/p>\n<p>\u201cA planilha de servi\u00e7os quantificados e or\u00e7ados que comp\u00f5e os documentos de licita\u00e7\u00e3o dever\u00e1 ser utilizada como refer\u00eancia para a apresenta\u00e7\u00e3o de proposta comercial por parte das licitantes. Cabe ressaltar que as licitantes devem obrigatoriamente realizar levantamento pr\u00f3prio de todas as quantidades bem como or\u00e7ar cada um dos itens e subitens de planilha\u201d. (grifo nosso)<\/p>\n<p>Em seu \u00edtem 1.3.2 o anexo V &#8211; minuta de contrato, explicita:<\/p>\n<p>\u201cAs quantidades indicadas no Edital do Processo Licitat\u00f3rio Concorr\u00eancia n\u00ba 21E\/0006CC s\u00e3o meramente orientativas, cabendo \u00e0 CONTRATADA a responsabilidade pelo levantamento integral das mesmas\u201d.<\/p>\n<p><strong>As quantidades definidas na planilha or\u00e7ament\u00e1ria, para servi\u00e7os em equipamentos existentes, s\u00e3o resultado de nossa avalia\u00e7\u00e3o considerando suas condi\u00e7\u00f5es atuais, sendo ent\u00e3o definido para cada um uma composi\u00e7\u00e3o de pre\u00e7os unit\u00e1rios.<\/strong><\/p>\n<p><span style=\"font-style: inherit; font-weight: inherit;\"><strong>Considerando que a real extens\u00e3o dos servi\u00e7os em equipamentos somente ser\u00e1 poss\u00edvel ap\u00f3s \u00a0inspe\u00e7\u00e3o detalhada da Contratada, lhe caber\u00e1 informar \u00e0 Contratante as diverg\u00eancia detectadas atrav\u00e9s de laudo t\u00e9cnico, caracterizando os desvios em rela\u00e7\u00e3o aos quantitativos or\u00e7ados.<\/strong><\/span><\/p>\n<p><span style=\"font-style: inherit; font-weight: inherit;\"><strong>Caso o pleito da Contratada seja aceito, estes servi\u00e7os\/fornecimentos somente dever\u00e3o ser executados ap\u00f3s a formaliza\u00e7\u00e3o de termo aditivo contratual.<\/strong><\/span><\/p>\n<p><span style=\"font-style: inherit; font-weight: inherit;\"><strong>Com rela\u00e7\u00e3o aos demais quantitativos, estaremos disponibilizando os projetos em DWG para facilitar o levantamento e adiando a abertura dos envelopes para 09\/08\/2021.<\/strong><\/span><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">Rio de janeiro, 27 de julho de 2021<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>ADENDO IV<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc prorroga a data deste processo licitat\u00f3rio, conforme abaixo:<\/p>\n<ul style=\"text-align: center;\">\n<li style=\"text-align: left;\">Prorroga\u00e7\u00e3o do prazo de visita t\u00e9cnica, item 3.2.2 do Edital &#8211; at\u00e9 21\/07\/2021;<\/li>\n<li style=\"text-align: left;\"><em>3.2.2. <strong>A Visita T\u00e9cnica para vistoria \u00e9 obrigat\u00f3ria<\/strong>, devido as caracter\u00edsticas do local de execu\u00e7\u00e3o das obras, devendo ser realizada no per\u00edodo de<strong> <u>09\/07\/2021 a 21\/07\/2021<\/u><\/strong>, com agendamento por meio do endere\u00e7o eletr\u00f4nico poloeducacional-compras@sesc.com.br, citando o n\u00famero desta licita\u00e7\u00e3o. A visita ser\u00e1 acompanhada por representante da Escola Sesc (Anexo IV).<\/em><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">Rio de janeiro, 15 de julho de 2021<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>ADENDO III<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc responde ao questionamento apresentado por empresa interessada em participar desta licita\u00e7\u00e3o.<\/p>\n<p><strong>Pergunta:<\/strong> No item 3.2.1. b), as ARTs (que contemplem \u201cExecu\u00e7\u00e3o de instala\u00e7\u00e3o ou reforma de subesta\u00e7\u00f5es com tens\u00e3o igual ou superior a 13,8kV\u201d) constituintes do CAT com registro de atestado do profissional devem constar que a empresa licitante (a nossa empresa) efetuou o servi\u00e7o, ou seja, foi a empresa contratada?<\/p>\n<p>Por exemplo, se o profissional que comp\u00f5e o nosso quadro t\u00e9cnico possui ARTs de \u201cExecu\u00e7\u00e3o de instala\u00e7\u00e3o ou reforma de subesta\u00e7\u00f5es com tens\u00e3o igual ou superior a 13,8kV\u201d, mas realizou esses servi\u00e7os sob outra empresa, o CAT com registro de atestado desse profissional vale de qualifica\u00e7\u00e3o t\u00e9cnica para a nossa empresa participar dessa licita\u00e7\u00e3o?<\/p>\n<p><strong>Resposta: Sim, desde que o profissional comprovadamente capacitado atrav\u00e9s das ART\/CAT fa\u00e7a parte do quadro da empresa, sendo necess\u00e1ria a comprova\u00e7\u00e3o de v\u00ednculo entre profissional e empresa.<\/strong><\/p>\n<p style=\"text-align: center;\">Rio de janeiro, 14 de julho de 2021<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>ADENDO II<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc responde aos questionamentos apresentados por empresas interessadas em participar desta licita\u00e7\u00e3o.<\/p>\n<p><strong>Pergunta:<\/strong> Acerca do item 3.2 (qualifica\u00e7\u00e3o t\u00e9cnica), al\u00ednea b:\u00a0\u00a0<strong><u>Execu\u00e7\u00e3o de instala\u00e7\u00e3o ou reforma de subesta\u00e7\u00f5es com tens\u00e3o igual ou superior a 13,8kV<\/u><\/strong><u>\u00a0<strong>Unid: Kva\u00a0 Quant: 2.800<\/strong><\/u>, solicitamos esclarecimentos em rela\u00e7\u00e3o ao detalhamento do que deve conter na Certid\u00e3o de Acervo t\u00e9cnico\/ Atestado em n\u00edvel de quantitativo de servi\u00e7os, equipamentos etc&#8230; ?<\/p>\n<p><strong>Resposta<\/strong><strong>: <\/strong><em>Esclarecemos que as comprova\u00e7\u00f5es da qualifica\u00e7\u00e3o t\u00e9cnica dever\u00e3o ser compat\u00edveis em qualidade e quantidade em 50% do objeto desta licita\u00e7\u00e3o. Os principais itens que ser\u00e3o levados em conta na avalia\u00e7\u00e3o ser\u00e3o: <\/em><em>Fornecimento e instala\u00e7\u00e3o de cabos de MT, inclusive execu\u00e7\u00e3o de testes e ensaios de isolamento e tens\u00e3o aplicada (aprox.. 1600 metros);<\/em><\/p>\n<p><em>Fornecimento e instala\u00e7\u00e3o de cabos de BT, bitola maior ou igual a 95mm\u00b2, inclusive execu\u00e7\u00e3o de testes e ensaios de isolamento (aprox..\u00a0 3.000 metros);<\/em><\/p>\n<p><em>Fornecimento e instala\u00e7\u00e3o de pain\u00e9is de m\u00e9dia tens\u00e3o com tens\u00e3o igual ou superior a 13,8 kV e pot\u00eancia igual ou superior a 2800 kVA;<\/em><\/p>\n<p><em>Fornecimento e instala\u00e7\u00e3o de pain\u00e9is de baixa tens\u00e3o tipo TTA e com pot\u00eancia igual ou superior a 2800 kVA;<\/em><\/p>\n<p><em>Execu\u00e7\u00e3o de manuten\u00e7\u00e3o, incluindo testes e ensaios em pain\u00e9is e transformadores de for\u00e7a de MT com tens\u00e3o igual ou superior a 13,8 kV e pot\u00eancia igual ou superior a 2800 kVA;<\/em><\/p>\n<p><em>Execu\u00e7\u00e3o de estudo de coordena\u00e7\u00e3o e seletividade de prote\u00e7\u00e3o em instala\u00e7\u00f5es el\u00e9tricas com tens\u00e3o igual ou superior a 13,8 kV e pot\u00eancia igual ou superior a 2800 kVA;<\/em><\/p>\n<p><em>Comissionamento de subesta\u00e7\u00f5es e instala\u00e7\u00f5es el\u00e9tricas com tens\u00e3o igual ou superior a 13,8 kV e pot\u00eancia igual ou superior a 2800 kVA.<\/em><\/p>\n<p style=\"text-align: center;\">Rio de janeiro, 13 de julho de 2021<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>ADENDO I<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc informa:<\/p>\n<ul style=\"text-align: center;\">\n<li style=\"text-align: left;\">Publica\u00e7\u00e3o de Anexo Ia revisado &#8211;\u00a0378-PLE1-RDCO-MAI21-00001-02 &#8211; MODERNIZA\u00c7\u00c3O DAS SUBESTA\u00c7\u00d5ES.<\/li>\n<\/ul>\n<p style=\"text-align: center;\">Rio de Janeiro, 09 de julho de 2021.<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong>CONCORR\u00caNCIA N.\u00ba 21E\/0006CC<\/strong><\/p>\n<p style=\"text-align: center;\">REUNI\u00c3O DE RECEBIMENTO DE ENVELOPES<\/p>\n<p style=\"text-align: center;\"><strong>Dia 29 de julho de 2021, \u00e0s 10:00 horas<\/strong><\/p>\n<p style=\"text-align: center;\">O Polo Educacional Sesc, entidade de direito privado, sem fins lucrativos, comunica a realiza\u00e7\u00e3o de Licita\u00e7\u00e3o, na modalidade <strong>CONCORR\u00caNCIA, do tipo<\/strong> <strong>MENOR PRE\u00c7O EXEQU\u00cdVEL<\/strong> <strong>em regime de empreitada por pre\u00e7o global<\/strong>. A presente licita\u00e7\u00e3o \u00e9 regida pela RESOLU\u00c7\u00c3O SESC N.\u00ba 1252\/12 de 06.JUN.12, publicada na se\u00e7\u00e3o III do Di\u00e1rio Oficial da Uni\u00e3o, n.\u00ba 144 de 26.JUL.12, para contrata\u00e7\u00e3o de empresa especializada para execu\u00e7\u00e3o das:<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\">Obras de Moderniza\u00e7\u00e3o das Subesta\u00e7\u00f5es El\u00e9tricas do Polo Educacional Sesc<\/p>\n<p style=\"text-align: center;\">&#8211;<\/p>\n<p style=\"text-align: center;\"><strong><u>VALOR DE REFER\u00caNCIA:<\/u><\/strong> R$ 5.582.749,16 (cinco milh\u00f5es, quinhentos e oitenta e dois mil, setecentos e quarenta e nove reais e dezesseis centavos).<\/p>\n<p style=\"text-align: center;\"><strong><u>EDITAL E ANEXOS:<\/u><\/strong> Poder\u00e3o ser retirados no endere\u00e7o eletr\u00f4nico www.escolasesc.com.br \u2013 em Licita\u00e7\u00f5es, e apresentar seus envelopes contendo os documentos e propostas no mesmo local, conforme data-hora acima especificada.<\/p>\n<p style=\"text-align: center;\">Rio de Janeiro, 07 de julho de 2021.<\/p>\n<p style=\"text-align: center;\"><a href='https:\/\/drive.google.com\/drive\/folders\/1GMlbhze-0kiYJawx9dY8ZzmYEkZrS5Hp?usp=sharing' class='small-button smallred' target=\"_blank\">Clique aqui para acessar os anexos<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u00a0RESULTADO DA FASE\u00a0HABILITA\u00c7\u00c3O E JULGAMENTO FINAL O Polo Educacional Sesc informa o resultado da habilita\u00e7\u00e3o da licita\u00e7\u00e3o em ep\u00edgrafe: &nbsp; Empresa Habilitada: TORRES ENGENHARIA E CONSULTORIA LTDA &nbsp; Diante do exposto, O Polo Educacional Sesc informa o resultado Final da licita\u00e7\u00e3o acima referenciada: Julgamento Final:\u00a0\u00a0 TORRES ENGENHARIA E CONSULTORIA LTDA &nbsp; Rio de Janeiro, 13 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[18],"tags":[],"class_list":["post-6910","post","type-post","status-publish","format-standard","hentry","category-concorrencias"],"_links":{"self":[{"href":"https:\/\/www.sesc.com.br\/poloeducacional\/wp-json\/wp\/v2\/posts\/6910","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sesc.com.br\/poloeducacional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sesc.com.br\/poloeducacional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sesc.com.br\/poloeducacional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sesc.com.br\/poloeducacional\/wp-json\/wp\/v2\/comments?post=6910"}],"version-history":[{"count":0,"href":"https:\/\/www.sesc.com.br\/poloeducacional\/wp-json\/wp\/v2\/posts\/6910\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.sesc.com.br\/poloeducacional\/wp-json\/wp\/v2\/media?parent=6910"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sesc.com.br\/poloeducacional\/wp-json\/wp\/v2\/categories?post=6910"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sesc.com.br\/poloeducacional\/wp-json\/wp\/v2\/tags?post=6910"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}